Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-35925
Titel: Drug-coated balloons for small coronary artery disease in patients with chronic kidney disease: a pre-specified analysis of the BASKET-SMALL 2 trial
VerfasserIn: Mahfoud, Felix
Farah, Ahmed
Ohlow, Marc-Alexander
Mangner, Norman
Wöhrle, Jochen
Möbius-Winkler, Sven
Weilenmann, Daniel
Leibundgut, Gregor
Cuculi, Florim
Gilgen, Nicole
Kaiser, Christoph
Cattaneo, Marco
Scheller, Bruno
Jeger, Raban V.
Sprache: Englisch
Titel: Clinical Research in Cardiology
Verlag/Plattform: Springer Nature
Erscheinungsjahr: 2022
Freie Schlagwörter: Drug-coated balloon
Renal insufficiency
Revascularization strategies
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Background Data on the safety and efcacy of drug-coated balloon (DCB) compared to drug-eluting stent (DES) in patients with chronic kidney disease (CKD) are scarce, particularly at long term. This pre-specifed analysis aimed to investigate the 3-year efcacy and safety of DCB versus DES for small coronary artery disease (<3 mm) according to renal function at baseline. Methods BASKET-SMALL-2 was a large multi-center, randomized, controlled trial that tested the efcacy and safety of DCBs (n=382) against DESs (n=376) in small vessel disease. CKD was defned as eGFR<60 ml/min/1.73m2 . The primary endpoint was the composite of cardiac death, non-fatal myocardial infarction, and target vessel revascularization (MACE) during 3 years. Results A total of 174/758 (23%) patients had CKD, out of which 91 were randomized to DCB and 83 to DES implantation. The primary efcacy outcome during 3 years was similar in both, DCB and DES patients (HR 0.98; 95%-CI 0.67–1.44; p=0.937) and patients with and without CKD (HR 1.18; 95%-CI 0.76–1.83; p=0.462), respectively. Rates of cardiac death and all-cause death were signifcantly higher among patients with CKD but not afected by treatment with DCB or DES. Major bleeding events were lower in the DCB when compared to the DES group (12 vs. 3, HR 0.26; 95%-CI 0.07–0.92; p=0.037) and not infuenced by presence of CKD. Conclusions The long-term efcacy and safety of DCB was similar in patients with and without CKD. The use of DCB was associated with signifcantly fewer major bleeding events (NCT 01574534).
DOI der Erstveröffentlichung: 10.1007/s00392-022-01995-3
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-359257
hdl:20.500.11880/32746
http://dx.doi.org/10.22028/D291-35925
ISSN: 1861-0692
1861-0684
Datum des Eintrags: 6-Apr-2022
Bezeichnung des in Beziehung stehenden Objekts: Supplementary Information
In Beziehung stehendes Objekt: https://static-content.springer.com/esm/art%3A10.1007%2Fs00392-022-01995-3/MediaObjects/392_2022_1995_MOESM1_ESM.docx
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Innere Medizin
Professur: M - Prof. Dr. Michael Böhm
M - Prof. Dr. Bruno Scheller-Clever
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
Mahfoud2022_Article_Drug-coatedBalloonsForSmallCor.pdf943,94 kBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons