Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-39398
Titel: Comparison of the Accuracy of 2D and 3D Templating for Revision Total Hip Replacement
VerfasserIn: Winter, Philipp
Fritsch, Ekkehard
König, Jochem
Wolf, Milan
Landgraeber, Stefan
Orth, Patrick
Sprache: Englisch
Titel: Journal of Personalized Medicine
Bandnummer: 13
Heft: 3
Verlag/Plattform: MDPI
Erscheinungsjahr: 2023
Freie Schlagwörter: revision arthroplasty
hip (joint)
reinforcement cage
Burch Schneider
2D
3D
computed tomography
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Introduction: Revision hip arthroplasty is a challenging surgical procedure, especially in cases of advanced acetabular bone loss. Accurate preoperative planning can prevent complications such as periprosthetic fractures or aseptic loosening. To date, the accuracy of three-dimensional (3D) versus two-dimensional (2D) templating has been evaluated only in primary hip and knee arthroplasty. Methods: We retrospectively investigated the accuracy of 3D personalized planning of reinforcement cages (Burch Schneider) in 27 patients who underwent revision hip arthroplasty. Personalized 3D modeling and positioning of the reinforcement cages were performed using computed tomography (CT) of the pelvis of each patient and 3D templates of the implant. To evaluate accuracy, the sizes of the reinforcement cages planned in 2D and 3D were compared with the sizes of the finally implanted cages. Factors that may potentially influence planning accuracy such as gender and body mass index (BMI) were analyzed. Results: There was a significant difference (p = 0.003) in the accuracy of correct size prediction between personalized 3D templating and 2D templating. Personalized 3D templating predicted the exact size of the reinforcement cage in 96.3% of the patients, while the exact size was predicted in only 55.6% by 2D templating. Regarding gender and BMI, no statistically significant differences in planning accuracy either for 2D or 3D templating were observed. Conclusion: Personalized 3D planning of revision hip arthroplasty using Burch Schneider reinforcement cages leads to greater accuracy in the prediction of the required size of implants than conventional 2D templating.
DOI der Erstveröffentlichung: 10.3390/jpm13030510
URL der Erstveröffentlichung: https://www.mdpi.com/2075-4426/13/3/510
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-393983
hdl:20.500.11880/35522
http://dx.doi.org/10.22028/D291-39398
ISSN: 2075-4426
Datum des Eintrags: 29-Mär-2023
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Orthopädie
Professur: M - Prof. Dr. Stefan Landgraeber
M - Prof. Dr. Henning Madry
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
jpm-13-00510-v2.pdf40,14 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons