Titel: Comparison Between Pipeline Embolization Device and Derivo Embolization Device for the Treatment of Unruptured Cerebral Aneurysms: A Single-Center Analysis
VerfasserIn: Naziri, Weis
Gheorghe, Stefan Daniel
Dietrich, Philipp
Kettner, Michael
Mühl-Benninghaus, Ruben
Yilmaz, Umut
Reith, Wolfgang
Simgen, Andreas
Sprache: Englisch
Titel: Journal of Clinical Medicine
Bandnummer: 15
Heft: 9
Verlag/Plattform: MDPI
Erscheinungsjahr: 2026
Freie Schlagwörter: flow diverter
intracranial aneurysm
PED
DED
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Background: The introduction of flow diverters (FDs) has greatly enhanced the treatment of cerebral aneurysms. This study compares two FDs, the Pipeline Embolization Device (PED) and the Derivo Embolization Device (DED), in terms of technical, angiographic and clinical aspects. Methods: A total of 103 patients with unruptured aneurysms were treated with the PED (n = 56) and DED (n = 47) between 2012 and 2019. Aneurysm occlusion, procedural complications, occurrence of In-stent stenosis and clinical outcome were evaluated retrospectively. Results: Implantation of the flow diverters was technically successful in all patients. There were no significant differences between baseline characteristics and aneurysm morphology. Angiographic follow-up was available with a median short-term follow-up of 3 months and a median long-term follow-up time of 16 months. Adequate aneurysm occlusion at long-term follow-up was substantially but not significantly greater with the DED (95.8%, 45/47) compared to the PED (87.5%, 49/56) (p = 0.084). In-stent stenoses were significantly less frequent with the DED (29.8%; 14/47) than with the PED (53.6%, 30/57) at short-term follow-up (p = 0.017), although moderate and asymptomatic overall. Thromboembolic or hemorrhagic events occurred in 10.7% (6/56) of cases with the PED and 8.5% (4/47) with the DED (p = 0.752). Morbidity rates were similar between devices (PED 3.6% (2/56), DED 2.1% (1/47), p = 1.0). There was no procedural mortality. Conclusions: Clinical outcomes and complications were comparable between the PED and DED while aneurysm occlusion was considerably greater at long-term follow-up and in-stent stenosis significantly less frequent at short-term follow-up with the DED. The surface-modified design of the DED may contribute to reduced thrombogenicity and early advantages in preventing in-stent stenosis. Further comparative studies are necessary to investigate these findings, particularly comparing surface-modified flow diverters with newer-generation devices featuring true coatings.
DOI der Erstveröffentlichung: 10.3390/jcm15093519
URL der Erstveröffentlichung: https://doi.org/10.3390/jcm15093519
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-478292
hdl:20.500.11880/41833
http://dx.doi.org/10.22028/D291-47829
ISSN: 2077-0383
Datum des Eintrags: 13-Mai-2026
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Radiologie
Professur: M - Prof. Dr. Wolfgang Reith
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
jcm-15-03519.pdf224,32 kBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons