Abstract: Electricity storage systems, whether electric vehicles or stationary battery storage systems, stabilize the electricity supply grid with their flexibility and thus drive the energy transition forward. Grid peak power demand has a high impact on the energy bill for commercial electricity consumers. Using battery storage capacities (EVs or stationary battery systems) can help to reduce these peaks, applying peak shaving. This study aims to address the potential of peak shaving using a PV plant and smart unidirectional and bidirectional charging technology for two fleets of electric vehicles and two comparable configurations of stationary battery storage systems on the university campus of Saarland University in Saarbrücken as a case study. Based on an annual measurement of the grid demand power of all consumers on the campus, a simulation study was carried out to compare the peak shaving potential of seven scenarios. For the sake of simplicity, it was assumed that the vehicles are connected to the charging station during working hours and can be charged and discharged within a user-defined range of state of charge. Furthermore, only the electricity costs were included in the profitability analysis; investment and operating costs were not taken into account. Compared to a reference system without battery storage capacities and a PV plant, the overall result is that the peak-shaving potential and the associated reduction in total electricity costs increases with the exclusive use of a PV system (3.2%) via the inclusion of the EV fleet (up to 3.0% for unidirectional smart charging and 8.1% for bidirectional charging) up to a stationary battery storage system (13.3%).
DOI der Erstveröffentlichung: 10.3390/en17010047
URL der Erstveröffentlichung: https://doi.org/10.3390/en17010047
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-413974
hdl:20.500.11880/37119
http://dx.doi.org/10.22028/D291-41397
ISSN: 1996-1073
Datum des Eintrags: 11-Jan-2024
Fakultät: NT - Naturwissenschaftlich- Technische Fakultät
Fachrichtung: NT - Systems Engineering
Professur: NT - Prof. Dr. Georg Frey
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
energies-17-00047.pdf1,89 MBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons