Abstract: Background Long diseased vessel segments of peripheral arteries may display irregular shapes with different diameters. The aim of this study was to investigate inhibition of neointimal proliferation in porcine peripheral vessels with different diameters covered by one single hypercompliant drug-coated balloon (HCDCB), compared to conventional drug-coated balloons (DCB), each selected according to the respective vessel diameter. Methods and results Neointimal proliferation was stimulated in proximal and distal segments of the peripheral arteries by balloon overstretch and stent implantation. Inhibition of neointimal proliferation by one single HCDCB was compared to two vessel diameter-adjusted DCB per artery and to one single uncoated hyper-compliant balloon (HCB). Sixteen HCB, 16 HCDCB, and 32 DCB were used in 16 arteries each. Quantitative angiography (QA), optical coherence tomography (OCT) and histology showed a similar anti-restenotic effect for one HCDCB compared to two vessel diameter-adjusted DCB in narrow distal and wider proximal segments (QA diameter stenosis: 18.7±12.3% vs. 22.8±15.5%, p = 0.535; OCT area stenosis: 21.4±11.6% vs. 23.6±12.3%, p = 0.850; histomorphometry diameter stenosis: 27.5±7.1% vs. 26.9±8.0%, p = 0.952) and indicated significant inhibition of neointimal proliferation by HCDCB vs. uncoated HCB (QA diameter stenosis: 18.7±12.3% vs. 30.3±16.7%, p = 0.008; OCT area stenosis: 21.4±11.6% vs. 34.7±16.0%, p = 0.004; histomorphometry diameter stenosis: 27.5±7.1% vs. 32.5±8.5%, p = 0.038). Conclusions HCDCB were found to be similar effective as DCB in inhibiting neointimal proliferation in vessel segments with different diameters. One single long HCDCB may allow for treatment of segments with variable diameters, and thus, replace the use of several vessel diameteradjusted DCB.
DOI of the first publication: 10.1371/journal.pone.0280206
URL of the first publication: https://doi.org/10.1371/journal.pone.0280206
Link to this record: urn:nbn:de:bsz:291--ds-418149
hdl:20.500.11880/37406
http://dx.doi.org/10.22028/D291-41814
ISSN: 1932-6203
Date of registration: 27-Mar-2024
Faculty: M - Medizinische Fakultät
Department: M - Innere Medizin
Professorship: M - Prof. Dr. Bruno Scheller-Clever
Collections:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Files for this record:
File Description SizeFormat 
journal.pone.0280206.pdf1 MBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons