Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen:
doi:10.22028/D291-42198
Titel: | Durability of Tricuspid Valve Repair in Patients Undergoing Left Ventricular Assist Device Implantation |
VerfasserIn: | Färber, Gloria Schwan, Imke Kirov, Hristo Rose, Marcel Tkebuchava, Sophie Schneider, Ulrich Caldonazo, Tulio Diab, Mahmoud Doenst, Torsten |
Sprache: | Englisch |
Titel: | Journal of Clinical Medicine |
Bandnummer: | 13 |
Heft: | 5 |
Verlag/Plattform: | MDPI |
Erscheinungsjahr: | 2024 |
Freie Schlagwörter: | left ventricular assist device tricuspid regurgitation |
DDC-Sachgruppe: | 610 Medizin, Gesundheit |
Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
Abstract: | Abstract: Objectives: Benefits of tricuspid valve repair (TVR) in left ventricular assist device (LVAD) patients have been questioned. High TVR failure rates have been reported. Remaining or recurring TR was found to be a risk factor for right heart failure (RHF). Therefore, we assessed our experience. Methods: Since 12/2010, 195 patients have undergone LVAD implantation in our center. Almost half (n = 94, 48%) received concomitant TVR (LVAD+TVR). These patients were included in our analysis. Echocardiographic and clinical data were assessed. Median follow-up was 2.8 years (7 days–0.6 years). Results were correlated with clinical outcomes. Results: LVAD+TVR patients were 59.8 ± 11.4 years old (89.4% male) and 37.3% were INTERMACS level 1 and 2. Preoperative TR was moderate in 28 and severe in 66 patients. RV function was severely impaired in 61 patients reflected by TAPSE-values of 11.2 ± 2.9 mm (vs. 15.7 ± 3.8 mm in n = 33; p < 0.001). Risk for RHF according to EUROMACS-RHF risk score was high (>4 points) in 60 patients, intermediate (>2–4 points) in 19 and low (0–2 points) in 15. RHF occurred in four patients (4.3%). Mean duration of echocardiographic follow-up was 2.8 ± 2.3 years. None of the patients presented with severe and only five (5.3%) with moderate TR. The vast majority (n = 63) had mild TR, and 26 patients had no/trace TR. Survival at 1, 3 and 5 years was 77.4%, 68.1% and 55.6%, 30-day mortality was 11.7% (n = 11). Heart transplantation was performed in 12 patients (12.8%). Conclusions: Contrary to expectations, concomitant TVR during LVAD implantation may result in excellent repair durability, which appears to be associated with low risk for RHF. |
DOI der Erstveröffentlichung: | 10.3390/jcm13051411 |
URL der Erstveröffentlichung: | https://doi.org/10.3390/jcm13051411 |
Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-421986 hdl:20.500.11880/37870 http://dx.doi.org/10.22028/D291-42198 |
ISSN: | 2077-0383 |
Datum des Eintrags: | 17-Jun-2024 |
Fakultät: | M - Medizinische Fakultät |
Fachrichtung: | M - Chirurgie |
Professur: | M - Keiner Professur zugeordnet |
Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
Datei | Beschreibung | Größe | Format | |
---|---|---|---|---|
jcm-13-01411.pdf | 1,15 MB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons