Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen:
doi:10.22028/D291-48148 | Titel: | Simplification of a Three-Constant Intraocular Lens Calculation Formula to a Single-Constant Approach: The Haigis Formula |
| VerfasserIn: | Langenbucher, Achim Szentmáry, Nóra Cayless, Alan Fassbind, Benjamin Bolzern, Iwan Hoffmann, Peter Wendelstein, Jascha Armin |
| Sprache: | Englisch |
| Titel: | Diagnostics |
| Bandnummer: | 16 |
| Heft: | 12 |
| Verlag/Plattform: | MDPI |
| Erscheinungsjahr: | 2026 |
| Freie Schlagwörter: | intraocular lens Haigis formula cataract surgery biometry formula optimization |
| DDC-Sachgruppe: | 610 Medizin, Gesundheit |
| Dokumenttyp: | Journalartikel / Zeitschriftenartikel |
| Abstract: | Background/Objectives: To derive and validate a simplified modification of the Haigis intraocular lens (IOL) power calculation formula by reducing the three-constant effective lens position (ELP) model to a single constant while introducing an optimized keratometer index and axial length correction. Methods: In this retrospective study, a large multicentric dataset (Dataset 1; 22,466 eyes, 113 IOL models) was used to optimize the Haigis constant triplet and keratometer index using nonlinear programming with Cooke’s axial length correction. A second independent dataset (Dataset 2; 3181 eyes, six IOL models) was used for cross-validation. Three approaches were compared: classical Haigis, modified triplet, and two single-constant models acting on IOL power (H1) or ELP (H2). Results: The optimized keratometer index (1.3296 ± 0.0003) was significantly lower than the classical value, indicating systematic overestimation of corneal power. Modified triplet and single-constant approaches achieved comparable or slightly lower prediction errors than the classical formula. The H1 approach showed marginally superior performance. Bootstrapping confirmed parameter stability. Conclusions: A single-constant modification of the Haigis formula incorporating an optimized keratometer index and axial length correction maintains prediction accuracy while simplifying clinical implementation. |
| DOI der Erstveröffentlichung: | 10.3390/diagnostics16121938 |
| URL der Erstveröffentlichung: | https://doi.org/10.3390/diagnostics16121938 |
| Link zu diesem Datensatz: | urn:nbn:de:bsz:291--ds-481485 hdl:20.500.11880/42110 http://dx.doi.org/10.22028/D291-48148 |
| ISSN: | 2075-4418 |
| Datum des Eintrags: | 29-Jun-2026 |
| Fakultät: | M - Medizinische Fakultät |
| Fachrichtung: | M - Augenheilkunde |
| Professur: | M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher M - Prof. Dr. med. Nóra Szentmáry |
| Sammlung: | SciDok - Der Wissenschaftsserver der Universität des Saarlandes |
Dateien zu diesem Datensatz:
| Datei | Beschreibung | Größe | Format | |
|---|---|---|---|---|
| diagnostics-16-01938-v2.pdf | 1,3 MB | Adobe PDF | Öffnen/Anzeigen |
Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons